Standard Timber Drying House
■ The walls of the House are built by soil.
■ We use Fully-automatic, semi-automatic and manual controlling system
■ The house doors are bisect or hang designed to keep perfect seal and convenient unseal.
■ feed material by forklift truck and track dolly.
■ The heating mediums are steam, high-temperature water, hot oil and electricity.
The drying houses are built by concrete, heat preservation layer, bricks and other material. We adopted perlite granule to be heat preservation material.

Xinan Drying House

After House In
Main Parameter of Drying house Model XN-20 XN-30 XN-40 XN-50 XN-60 XN-80 XN-100 XN-150 XN-200 Wood Bulk 20 30 40 50 60 80 100 150 200 Power 6 6 9 9 9 15 15 21 27 Model Code of Xinan Drying House Code of Drying House Medium Wall Controlling Method Model Code Steam Heating Full Aluminium Automatic Control XNQ—MaA20/30/40/50/60/80/100/150/200 Semi-automatic Control XNQ—MaS20/30--------------/200 Manual Control XNQ—MaH20/30--------------/200 Mixed Bricks Automatic Control XNQ—BA20/30---------------/200 Semi-automatic Control XNQ—BS20/30---------------/200 Manual Control XNQ—BH20/30---------------/200 Water Heating Full Aluminium Automatic Control XNS—MaA20/30--------------/200 Semi-automatic Control XNS—MaS20/30--------------/200 Manual Control XNS—MaH20/30--------------/200 Mixed Bricks Automatic Control XNS—BA20/30---------------/200 Semi-automatic Control XNS—BS20/30---------------/200 Manual Control XNS—BH20/30---------------/200 Stove Gas Full Aluminium Manual Control XNL—MaH10/15/20/30/40 Mixed Bricks Manual Control XNL—BH10/15/20/30/40 Oil Heating Full Aluminium Automatic Control XNY—MaA20/30--------------/200 Semi-automatic Control XNY—MaS20/30--------------/200 Manual Control XNY—MaH20/30--------------/200 Mixed Bricks Automatic Control XNY—BA20/30---------------/200 Semi-automatic Control XNY—BS20/30---------------/200 Manual Control XNY—BH20/30---------------/200 Electricity Heating Full Aluminium Automatic Control XND—MaA10/20/30/40/50 Semi-automatic Control XND—MaS10/---------------/50 Manual Control XND—MaH10/---------------/50 Mixed Bricks Automatic Control XND—BA10/----------------/50 Semi-automatic Control XND—BS10/----------------/50 Manual Control XND—BH10/----------------/50 Electric Tank Semi-automatic Control XINAN—EC×(×1 to 8blowers) Controlling Apparatus Semi-automatic XINAN—2000D Monitor Common Type XINAN—TM2000 Monitor Use for business Inspect XINAN—MTH Monitor Business Inspect Controlling Type XINAN—MTH